In certain sensitive areas of industry, such as electronics assembly lines and semiconductor production, and sometimes in healthcare facilities, electrostatic discharge must be controlled to avoid the risk of explosion or damage to electronic equipment. In such cases flooring plays a vital role in ESD control.

What is ESD?

Before defining the antistatic function of ESD flooring, it is worth explaining what the ESD (electrostatic discharge) phenomenon is. ESD is the discharge of static electricity that occurs when an electric charge builds up on the surface of a material or of the human body. When that charge comes into contact with the ground or with another unbalanced element, a discharge occurs. The familiar example is the shock felt when a person walks across a carpet and then touches a door handle.

We usually explain the phenomenon in terms of discharge, but without charging there is no discharge. Observing the charging phenomenon (in volts) is as important as measuring the discharge (in ohms here).

What are the risks associated with ESD?

The risks associated with ESD fall into two categories: risks relating to protecting people, and risks relating to protecting electronic equipment.

First, protecting people means controlling and avoiding electrostatic discharge in order to prevent fire and explosion under production conditions involving vapours, gases, powders and flammable liquids, such as in ATEX environments.

In hospital environments, controlling ESD is essential to prevent potential damage to equipment (MRI scanners, scanners and so on), to prevent possible explosion risks linked to anaesthetic gases (now increasingly rare) and to avoid dust build-up so as to achieve the highest levels of cleanliness.

In industry, a person can feel an electrostatic discharge of 3,000 volts, yet some electronic devices (printed circuit boards, semiconductors and so on) can be affected by discharges below 100 volts, and very sensitive devices by interference below 10V. This may not only directly affect quality on the production line but also create weaknesses and latent faults that impair equipment performance and can even severely limit its service life. A satellite carrying a potentially defective circuit board, for example, is not something we can afford to send into space.

ESD flooring: how is performance monitored?

Before discussing flooring solutions, controlling ESD in a protected environment must form part of a comprehensive control programme that includes earthing of all equipment (workbenches, tools, trolleys and so on), earthing of personnel (PPE, ESD shoes, ESD wrist straps, gloves and so on), workstation ionisation, employee training and regular audits.

Above all, ESD flooring is only effective if the operator wears ESD shoes (with the person, the ESD shoes and the floor forming a system) or uses another system that allows personnel to be earthed through the floor. The floor is the last line of defence in an ESD system for eliminating charge and conducting it to earth.

Two factors need to be considered under ESD standards:

In other words, the floor will allow an operator moving in the area to accumulate charge to a greater or lesser extent. This factor is measured in volts. Depending on the standard applied, the charging voltage for ESD flooring must not exceed 2,000 volts or 100 volts.

The ability of the floor to conduct discharge to earth is more or less rapid, and this factor is measured in ohms. For flooring to be considered ESD, its resistance must not exceed 10^9 ohms. In addition, for operator safety, resistance must not fall below 5x10^4 ohms (for 210-220V electrical installations) or 2.5x10^4 ohms (for 110V installations).

Quantifying performance clearly requires a standard reference and a structured test procedure. A company setting up an EPA (electrostatic discharge protected area) must first select and define the standard best suited to its environment. Many standards relate to specific applications and/or regions: EN14041, IEC 61340, ANSI ESD S20.20 and others.

Gerflor experts will help you choose the right flooring solution in line with the regulations your organisation follows.

ESD and antistatic flooring: making the right choice

As noted above, the choice of flooring solution will first be based on the ESD standard selected and adapted to your organisation. However, the choice must also be guided by the conditions of use and installation:

Condition of the subfloor and installation

In a new-build project or when renovating an existing area, the quality of the subfloor and the ease of installation must be considered, to ensure the flooring choice meets short- and medium-term needs as well as the installation time, that is, installation in an occupied environment without disrupting production. For example, ESD resin systems used in refurbishment require production to stop during installation, whereas ESD blocks such as GTI can be installed alongside operations, with very little impact on productivity.

Traffic

Flooring must be selected to suit frequency, type of traffic (pedestrian and/or mechanical) and loads. For pedestrian traffic using manual pallet trucks, 2mm homogeneous ESD PVC flooring is a good fit. Where constraints are greater, the GTI EL5 block solution is the first choice.

Resistance to cleaning and decontamination procedures

By listing the maintenance products or chemicals used in the process, the floor must be tested for chemical resistance at the concentrations used. Over the years Gerflor has developed patented and innovative special maintenance treatment technologies that meet the chemical resistance constraints industrial manufacturers place on block and sheet solutions.

Maintenance

It is important to consider the long-term life of the floor from the point of view of ease of maintenance and repairability. Unlike epoxy or polyurethane resin, PVC solutions allow rapid repair (heat welding for small repairs such as cuts or impacts), and areas needing refurbishment can be replaced easily without interrupting production.

ESD and cleanrooms

Flooring must also meet other requirements, such as control of particle emissions to ISO 14644-1, control of biocontamination (antimicrobial flooring), ease of decontamination and control of outgassing. Drawing on its cleanroom experience, Gerflor offers block and sheet solutions within its flooring ranges that are certified by independent laboratories, such as the Fraunhofer Institute, for safe use in cleanrooms.

Contact the GERFLOR experts to choose ESD and antistatic flooring: industry@gerflor.com

Discover the GERFLOR ESD flooring range

Contact our sales team

Please contact our sales team for information and advice on our flooring ranges.

I have read and accept the Privacy Policy.

Thank you for getting in touch

Our sales team will contact you as soon as possible to handle your request.

The Gerflor Group

Based in France, the Gerflor Group creates and manufactures innovative, design-led and sustainable resilient flooring, wall coverings and accessories, delivering technical and decorative turnkey solutions for a wide range of sectors.